在水泥或著是石灰砂漿中摻加進(jìn)適當(dāng)?shù)膿胶狭希热绶勖夯业锢啤⒐柙逋恋鹊纫怨?jié)約水泥或者是石灰用量,同時(shí),改善一下砂漿的和易性妈唯。下面小編為大家介紹一下
濟(jì)南抹面砂漿怎樣使用。
Appropriate admixtures such as fly ash and diatomite are added to the cement or lime mortar to save the cement or lime consumption and improve the workability of the mortar. The following editor will introduce how to use Jinan plastering mortar.
1飘含、抹面砂漿基層處理將板底或混凝土燃悍、砌塊等抹灰面上的雜物清理干凈,對(duì)于鋼筋混凝土鼓笨,應(yīng)將混凝土上的突出物剔除箭瘫,并將模板接縫處殘余的海綿條或膠帶紙等清理干凈。將基底上浮塵掃除与钳,提前用水噴淋隅凡,使之濕潤(rùn)。同時(shí)應(yīng)對(duì)施工部位的樓地面進(jìn)行清掃精柒,以利于抹灰后清理抹灰時(shí)產(chǎn)生的落地保溫砂漿绵捡。
1. Plastering mortar base course treatment: clean the sundries on the bottom of the slab or the plastering surface of concrete and blocks. For reinforced concrete, remove the protrusions on the concrete, and clean the residual sponge strips or adhesive tapes at the formwork joints. Remove the floating dust on the base and spray it with water in advance to make it wet. At the same time, the floor of the construction site shall be cleaned to facilitate the cleaning of the floor insulation mortar generated during plastering after plastering.
2、涂大旗界面劑或用拉毛在涂抹處理干凈的基層上滿涂界面劑或用拉毛探九,沿鋼筋混凝土與加氣混凝土接縫處抹3-4mm厚抹面砂漿安揣,隨即壓入400寬耐堿網(wǎng)格布每邊200寬,表面在用抹面砂漿抹平舶衬。然后滿涂界劑或用拉毛埠通。
2. Apply the big flag interface agent or roughen the surface of the cleaned base layer with the interface agent or roughen it. Apply 3-4mm thick plastering mortar along the joint between the reinforced concrete and the aerated concrete. Then press the 400 wide alkali resistant mesh cloth with a width of 200 on each side. The surface is plastered with the plastering mortar. Then apply the coating agent or roughen it.
3、抹面砂漿貼餅厚度控制點(diǎn)采用保溫砂漿設(shè)置逛犹,大小為20*20端辱,厚度為所需保溫層厚度,保溫層厚度控制點(diǎn)間距宜為1.5m以內(nèi)虽画。
3. The thickness control point of plastering mortar paste is set with thermal insulation mortar, with the size of 20 * 20 and the thickness of the required thermal insulation layer. The distance between the control points of thermal insulation layer thickness should be within 1.5m.

4舞蔽、保溫砂漿分層涂抹
4. Thermal insulation mortar layer by layer
(1)拌料:用人工按保溫砂漿:水=1:1(重)攪拌均勻成膏狀荣病,根據(jù)氣候溫度可自行掌握和易性,隨拌隨用渗柿。
(1) Mixing materials: manually mix the thermal insulation mortar: water = 1:1 (weight) to form a paste. According to the climate and temperature, the workability can be controlled by yourself, and the mixture can be used at any time.
(2)涂抹層保溫砂漿个盆。要求厚度不得高過(guò)1.5cm,壓實(shí)朵栖,表面留毛面颊亮。
(2) Apply thermal insulation mortar. It is required that the thickness shall not be more than 1.5cm, and it shall be compacted with rough surface left on the surface.
(3)二層形成初凝后(加鋼絲網(wǎng)),涂抹第三層陨溅,厚度不高過(guò)2cm终惑。注意:下一層涂抹一般間隔24,分層之間留毛面韵楼。
(3) After the initial setting of the second layer is formed (steel wire mesh is added), the third layer shall be coated with a thickness of no more than 2cm. Note: the next layer is generally applied at an interval of 24, leaving a rough surface between layers.
(4)抹面砂漿分層涂抹時(shí)淀祟,應(yīng)適度按壓,以確保層與層之間能形成有.效粘結(jié)决盔,但不可在同一部位來(lái)回抹壓酌铺。在涂抹中,發(fā)現(xiàn)有鼓包產(chǎn)生酿乾,應(yīng)及時(shí)剔除補(bǔ)抹辕洗。抹面砂漿
(4) When the plastering mortar is applied in layers, it shall be pressed moderately to ensure that there is a gap between layers Effective bonding, but cannot be plastered and pressed back and forth at the same position. In case of any bulge during coating, it shall be removed and repaired in time. Plastering mortar
5、鋪設(shè)耐堿玻纖網(wǎng)布
5. Laying alkali resistant glass fiber mesh
保溫砂漿表面收光時(shí)渣蒙,把耐堿玻纖網(wǎng)布用抹子直接壓在材料表面趋亡,同時(shí)收光,嚴(yán)禁漏鋪缔寒。耐堿玻纖網(wǎng)布鋪設(shè)時(shí)要求平整挪其、無(wú)皺褶,順序搭接感细,搭接寬度30-50mm;外檐鋪設(shè)時(shí)搭接寬度80-100mm;陽(yáng)角與保溫接茬處壓貼100mm寬的耐堿玻纖網(wǎng)布什猖。
When the surface of thermal insulation mortar is polished, the alkali resistant glass fiber mesh cloth shall be directly pressed on the material surface with a trowel, and the surface shall be polished at the same time. It is strictly prohibited to omit laying. The alkali resistant glass fiber mesh cloth shall be laid flat and without wrinkles, and shall be overlapped in sequence, with the overlapping width of 30-50mm; When laying the outer eaves, the overlapping width is 80-100mm; 100mm wide alkali resistant glass fiber mesh cloth shall be pressed and pasted at the external corner and insulation joint.
注意:當(dāng)施工期間,氣溫超過(guò)30℃的時(shí)候红淡,要在拌完成之后的3小時(shí)里面使用完畢不狮。為了方便配料,也為了減少施工中的切鋸工作量在旱,在建筑施工中摇零,要進(jìn)行排塊的設(shè)計(jì)。更多相關(guān)事項(xiàng)就來(lái)我們網(wǎng)站
http://m.bjtsdc.com咨詢了解吧桶蝎!
Note: when the temperature exceeds 30 ℃ during construction, it shall be used within 3 hours after mixing. In order to facilitate batching and reduce the workload of cutting and sawing during construction, the design of block arrangement shall be carried out during construction. For more information, please visit our website http://m.bjtsdc.com Consult and understand!